Moisture movement by air leakage (the exfiltration of interior moisture - laden air during heating periods and the infiltration of exterior moisture - laden air during cooling periods) is controlled by limiting
air leakage openings, controlling the interior levels of moisture during heating periods by utilizing controlled ventilation (dilution by air change) combined with source control (direct venting of clothes dryers as well as the use of subgrade vapor retarders under concrete floor slabs and bath and kitchen exhaust systems), controlling the interior levels of moisture during cooling periods by utilizing the dehumidification capabilities of mechanical cooling systems, and limiting controlled ventilation to minimum values established by indoor air quality concerns.
In mixed climates, building envelopes are constructed in an airtight manner to control
air leakage openings, to expedite air pressure control (depressurization of the building envelope above grade during the heating season, pressurization below grade to control ingress of soil gas and other pollutants, and pressurization of the building envelope during the cooling season) and to facilitate the dehumidification of indoor air during the cooling season, thereby limiting interior moisture levels.
Not exact matches
The management of
air starts by pressurizing the MKS cabin and then every
opening is scrutinized — every nook and cranny in the car, every hole, every weld, every sheet metal attachment — with the specific thought about where to accept
leakage and where to reject it.
Total apartment enclosure
air leakage performance was assessed by testing apartments in a fully unguarded configuration, that is, with neighboring apartments
open to the exterior.
pEUI: 13.7 kBtu / sf / yr
Air Leakage: 0.65 ACH50 Better Than Code: 74 % HERS Rating: 39 Grid - tied Solar Electric System, Solar Hot Water System Plumbed, Radiant Floors, Hydro
Air System, Energy Recovery Ventilator,
Open & Closed Cell Spray Foam Insulation, Rigid Insulation, ENERGY STAR Certified
Supply ventilation will tend to pressurize an interior space relative to the outdoors, causing inside
air to be forced out through
leakage openings located randomly throughout the building envelope.
Exhaust ventilation systems in all climatic zones draw outside
air from
leakage openings and pathways located randomly throughout the building envelope; thus, it is not possible to treat the outside
air before it enters the living space.
You can also test the total supply duct
leakage by isolating the supply side with a cardboard dam on the return
opening of the
air handler.
Heat waves lead to warmer indoor temperatures in three primary ways: conduction of heat from outdoors through the building envelope; transmission of radiant solar heat through windows; and the convection of warm
air through
open windows and doors and
air leakage.
These homes feature
open - cell spray foam insulation that reduces
air leakage and allows for smaller - sized HVAC units.
One thing to note is that due to the
open air design of this headset there is some sound
leakage — in both directions.