Sentences with phrase «airtightness layer»

1 The Rochestown House flats prior to the refurbishment; 2 aerated concrete blocks were chosen to form new build elements, including a new third storey that allows for more generous apartment sizes; 3 new triple - glazed windows were installed outside the masonry layer so that the external insulation could wrap around them, and help prevent thermal bridging; 4 the airtightness layer was moved to the outside of the structure by taping the joints of the existing concrete panels, then extending that tape up onto the aerated blocks in the new floor; 5 Aerobord platinum EPS external insulation being fitted to the original concrete panel walls; 6 & 7 the new window frames visible here in the external insulation layer, including Rockwool fire breaks; 8 openings for exhaust and supply intakes for the new Zehnder heat recovery ventilation system, seen here prior to being insulated and airtightened; 9 installation of the Bauder bitumen roofing membrane.
So the gaps around the beams were filled in, while the main airtightness layer was formed by plastering the walls to the outside.
He explains that the build team deployed a range of techniques to bolster the airtightness performance of the building before the installation of the airtightness layer itself.
The original external render provided the airtightness layer for the walls, while there is an air barrier in the floor slab too, sealed to the internal plaster.
Intello Plus vapour control and airtightness membrane on underside of roof fully taped at all joints with Tescon Vana airtightness tape and taped to Spanotech wall airtightness layer.

Not exact matches

Although the selected timber frame system includes an internal airtight layer, an additional membrane was applied to the room side of the panels in order to meet the airtightness target.
1 As work progresses on the foundations, a plate compactor is used to ensure a solid, stable base for the concrete slab; 2 pouring the concrete slab; 3 a cross-section of the wall build - up showing wet dash finish followed inside by external insulation, 215 mm solid block walls, sand - cement plaster and insulated plasterboard internally; 4 airtightness detailing around joist ends; 5 pro clima Intello airtightness system under counter battens to create a service void while minimising airtight layer damage by service penetrations; 6 a parge coat serves as the airtight layer on the inner face of the single leaf block walls.
a b c d e f g h i j k l m n o p q r s t u v w x y z