Sentences with phrase «generating units at»

The monthly survey Form EIA - 860M, «Monthly Update to Annual Electric Generator Report» supplements the annual survey form EIA - 860 data with monthly information that monitors the current status of existing and proposed generating units at electric power plants with 1 megawatt or greater of combined nameplate capacity.
American Electric installed three «scrubbers» at its largest power - generating unit at its John Amos Plant in West Virginia.

Not exact matches

HP is busily cutting itself into two companies while IBM generates press releases about acquisitions and new Watson business units at a fearsome clip.
I must sell 2.85 million bottles per year, at a wholesale price of $ 7 per unit, to generate $ 20 million in sales.
Their technology enables the sale of surplus renewable energy generated at residential and commercial developments (including multi - unit / multi-tenanted) and at homes and businesses connected to existing electricity distribution networks, or within micro-grids.
Avista owns a 15 - per - cent - stake in two of the four units at the Colstrip plant in Montana — a major coal - mining state — and plans to use them for electricity production until 2035, said a spokesperson for the company that also operates hydroelectric dams, natural gas and biomass generating plants and wind turbines.
In addition to hosting job fairs at the base, where 12,000 soldiers are stationed, Starbucks conducts regular plant tours for service members, maintains an Adopt a Unit program and supports the annual Fisher House Golf Tournament, which generates funds to aid families of patients receiving care at military and Veterans Administration medical centers.
«We hope this project allows us to generate data to show that implementing regenerative agriculture practices results in improved outcomes — including economic resiliency and long - term benefits for farmers,» said Carla Vernón, president of the operating unit at Annie's, also owned by parent company General Mills.
«Other than the Army - Navy football game, no event generates as much interest and support at the academy as brigade boxing,» says Andy Haffele, who won the 195 - pound title this year and will soon join the SEALs, the Navy's elite covert fighting unit.
There has already been a smart money move triggered on the under for tonight's Spurs / Thunder game at BetOnline (15 - 11, +2.65 units), and our All - Pro members should check in prior to tip - off to see if any further betting systems have been generated.
This has been a good season for «betting against the public» — as evidenced by Sports Insights Square Plays — which have generated +32 units for this season, at the time of this writing.
Planned birth at home, in a free standing midwifery unit, or in an alongside midwifery unit generates incremental cost savings compared with planned birth in an obstetric unit
«These findings raise important questions relating to the processes that other venomous animals may have used to generate their venom toxins,» wroteNicholas Casewell, senior lecturer and Wellcome Trust research fellow with the Alistair Reid Venom Research Unit at the Liverpool School of Tropical Medicine, in a summary dispatch published alongside the Current Biology paper.
He adds that it looks like BLP could be in production, at first with megawatt stationary units, and generating revenue by the end of 2017.
Commercial work now accounts for 93 percent of the archaeological research done in the United Kingdom, and academics must take note of the data generated by contract units, says Kenneth Aitchison, head of projects and professional development at the Institute for Archaeologists, the body representing commercial archaeologists in Britain.
The researchers, including some at Esri, combined information on geology and vegetation to generate nearly 4,000 «ecological land units».
«(ii) include at least 2 electric generating units, each with a nameplate generating capacity of 250 megawatts or greater, that capture, inject, and sequester carbon dioxide into geologic formations other than oil and gas fields; and
The final aim is improving therapeutic effect and defining rationalized drug combinations with immune checkpoints and proprietary molecules developed by collaborators, including novel immunomodulatory approaches generated at our unit.
To improve the ability to generate maximum force, the athlete does need to engage in both maximum effort lifting (to improve absolute power peak and motor unit synchronization) and dynamic effort lifting (to improve motor unit synchronization and speed of contraction), the former of which includes maximal or near maximal stimulus, the latter of which includes lower weight (~ 50 - 60 % of maximum) moved at maximum velocity.
In the end, third - graders, who get tested the most, take a whopping 14 standardized tests per year, in addition to «exit tickets» — teacher - generated assessments at the end of a unit of study.
Teachers can incorporate way - in books at the beginning of an instructional unit lesson to generate student interest and «promote student exploration of topics across the curriculum» (Bintz, 2011, p. 35).
Featuring concrete, hands - on activities that can be completed efficiently at the start of a unit, lesson, or topic, Activators help to: • Increase engagement in learning • Support a well - paced lesson • Generate connections to prior knowledge • Provide students with opportunities to practice skills and deepen understandings • Support formative assessment Although Activators have different formats, they all share two key components: individual think time and purposeful social interaction, which support students to develop quality responses to content and ideas while engaging with peers.
Production Of This Highly Individual And Increasing Rare Model Started In The December Of 1989 And Ran Until The March Of 1990, With This Final Run Of Limited Vehicles Fitted With The Already Legendary S14 Engine, However The BMW M Division Increased The Engine Displacement To A Two And A Half Litre Unit, That At Time Of Build Generated A Rather Healthy 238 Brake Horse Power At 7000rpm And 177 lb ft Of Torque At 4750 RPM, That Would Accelerate The Driver And Passengers From 0 - 62 In 6.1 Seconds And Climb To An Impressive Top Speed Of 155 MPH.
The new unit lays on peak torque of 500 Newton metres (369 lb - ft) between 1,500 and 4,500 rpm and generates maximum output of 250 kW / 340 hp at 5,500 rpm.
It is further incorporated with a turbocharging unit, which allows the vehicle to deliver a maximum power of 88.76 bhp at 5000rpm that helps in generating a peak torque output of 140Nm in the range of 1750 to 3500rpm.
According to reports, three petrol engines will be available at launch, a naturally aspirated 138bhp 1.8 - litre VTi generating 170Nm of torque, and two turbocharged 1.6 - litre four - cylinder units, developing 162bhp and 240Nm or 200bhp with 275Nm.
The new Beetle gets a 1.4 - litre TSI petrol motor with a direct injection unit, that generates 150 PS at 5,000 to 6,000 rpm and 250 Nm at 1,500 to 3,500 rpm, and is paired with the familiar seven - speed DSG (automatic).
There are diesels generating 90, 110, and 130 PS (89, 108, and 128 horsepower), and three gasoline units rated at 100, 130, and 205 PS (99, 128, and 202 horses).
However, unlike some other sports cars like the Porsche 718 Cayman and Audi TT RS, the Alfa Romeo's four - cylinder unit isn't amazingly refined at lower revs, and generates a fair bit of noise.
This unit makes 84.3 PS at 6,000 rpm and generates 115Nm at 4,000 rpm.
The 1.3 L unit makes 75PS at 4,000 rpm and generates 190Nm at 2,000 rpm.
This unit makes 110PS at 5,000 rpm and generates 170Nm at 2,000 - 4,000 rpm.
The wizards from Affalterbach installed a custom quad - cam head generating twice the torque at half the revs compared to the engine of origin, a 5.6 - litre unit.
According to Nielsen Bookscan, the organisation that collectes data on book sales in Ireland, sales for the year to date now stand at 3,142 units and have generated $ 27.276.72 at the till, giving an average selling price of $ 8.68.
Any profit generated on lumpsum invested amount is directly dependent on the market condition and the NAV at the time when the Mutual Fund units are redeemed.
Prior to the financial meltdown in 2008, KSP was generating distributable cash flow of at least $.77 unit per quarter.
The problem is that these secondary offerings depress the market price (secondary units must be priced at below market price to assure a successful underwriting) with their additional supply of units and the time lag to generate returns on the additional capital.
Nora is generated at the start of each round and any units on the field offer an additional bonus to nora revenue.
The game looks like it is on track to sell over 2.1 million units at retail on PS4 & XB1 during March 2016 and generate more than $ 130m in revenue at retail for Ubisoft in the US.
The game received an early price cut that may mean that sales were lower than expected but I still forecast the game to do well and the lower price as well as the demand for a new UFC title (Due to growing popularity of the sport) will help the game achieve somewhere close to 400,000 unit sales, albeit at a slightly lower ASP, meaning it may only generate $ 20 million at retail in the US.
Donovan has explored the effects of accumulation with these materials, at times utilizing hundreds of thousands of units such as straws, pins, or cups to generate perceptual phenomenon and subtle atmospheric effects.
Donovan has explored the effects of accumulation with these materials, at times utilizing hundreds of thousands of units such as straws, pins, or cups to generate perceptual phenomena and subtle atmospheric effects.
To help track monthly generator activity, EIA has started publishing a monthly updated preliminary inventory of all major generating units in the United States (essentially all generators located at power plants with a total plant capacity of 1 MW or greater) as a supplement to the annually updated inventory in the EIA - 860 Annual Electric Generator Report.
(1) deployment of technologies to capture and sequester carbon dioxide emissions from electric generating units or large industrial sources (except that assistance under this subtitle for such deployment shall be limited to the cost of retrofitting existing facilities with such technologies or the incremental cost of purchasing and installing such technologies at new facilities);
-- This subsection shall apply only to projects at the first 6 gigawatts of electric generating units, measured in cumulative generating capacity of such units, that receive allowances under this section.
-- This subsection shall apply only to the distribution of emission allowances for carbon capture and sequestration projects at electric generating units after the capacity threshold identified in subsection (c)(1) is reached.
«(ii) include at least 2 electric generating units, each with a nameplate generating capacity of 250 megawatts or greater, that capture, inject, and sequester carbon dioxide into geologic formations other than oil and gas fields; and
«(2) No additional projects shall be eligible for allowances under subsection (b)(1)(A)(ii) and (iv)(II) as of such time as the Administrator reports, pursuant to section 812 (d), that carbon capture and sequestration retrofit projects at electric generating units that are eligible for allowances under this section have been applied, in the aggregate, to the flue gas generated by 1 gigawatt of total cumulative generating capacity.
A capacity factor measures the amount of electricity actually produced by a generating unit compared to the electrical energy that could have been produced at continuous full power operation.
Assume a fixed rate of energy per unit time is being absorbed by and / or generated within an object; and at temperature T the object is in «heat transfer» equilbrium — i.e., the amount of outgoing energy per unit time is equal to the incoming radiation per unit time.
a b c d e f g h i j k l m n o p q r s t u v w x y z