A "blower door" is a device used to test the air tightness of buildings. It consists of a powerful fan that is fitted into an external doorway or window frame. When turned on, the fan sucks air out of the building causing air to come in from any unsealed gaps or cracks. This test helps identify areas where air leaks are occurring, which can then be sealed to improve energy efficiency and indoor comfort. Full definition
We can eliminate at least 30 % our electricity need, reducing CO2 and other Greenhouse Gas emissions and create green jobs at the same time by subsidizing comprehensive Energy Audits (with blower door tests using infra - red cameras to detect air leaks) weatherization and retrofitting residential and commercial buildings (See Green consortium and Home Start legislation.
Using blower door tests and infrared cameras, energy audits measure air leaks and detect air infiltration or missing insulation.
-- > All the details on how to measure blower door flows, estimate home tightness, and estimate fuel costs...
- Preparing the house for blower door testing (turning of combustion appliances, taking care of fireplaces, closing and opening the right doors,...)
Residential Pressure & Leakage Testing Manual, Retrotec, Inc An extensive manual on doing blower door testing
With the help of Gary Nelson of the Energy Conservatory in Minneapolis, we were able to conduct a first series of blower door tests.
I second JK's motion - we pretty much insist on blower door testing every foam job with which we are associated, and the results are often daunting - 100s, sometimes 1000s of wayward CFMs at 50 Pa, particularly with retrofits.
It basically does what a commercial blower door does, but less automatically and less accurately.
This DIY blower door uses a multi-speed furnace blower for the fan and is fitted into a window rather than a door.
If your utility offers blower door testing to identify air infiltration leaks, be sure to take advantage of it.
You don't have to worry about flow rate changing as the indoor to outdoor pressure changes, because the the furnace blower flow rates (at least the ones I've seen) change very little over the range of pressures used in blower door tests.
The first blower door test result was 0.59 air changes per hour (ACH), prior to insulating the envelope, which everyone was keen to improve on as it only marginally passed the passive house standard and was prior to fitting services, which are known to increase the risk of air leaks.
We were the first state to adopt an energy code that made blower door testing mandatory.
- If you are a home builder or contractor, having your own blower door means you can check frequently as construction progresses to see how tight things are and spot leaks while they are still easy to fix.
Partnering with ENERGY STAR is an opportunity for Raters expand their service offerings beyond simply providing HERS Ratings or individual performance tests (i.e. blower door tests).
The project is designed to achieve a maximum of.6 air changes per hour by blower door test.
Air leakage performance was measured via multipoint blower door testing.
A diagnostic initial blower door test, done when the external envelope was completed on one of the development's show houses, took place on December 12 and delivered a worldbeating result of 0.16 air changes per hour (ACH), well inside the passive house standard of 0.6 ACH and the best result this magazine has ever noted for a masonry building.
During initial stages of the renovation project, some iterations of guarded blower door testing were performed as well.
The essential blower door test kit for a wide range of professional airtightness testing needs, commercial and residential buildings.
and check out video of a successful blower door test from our friends at Dwell Development in Seattle.
In my opinion, EFL focuses more on the envelope and the home as a system than Energy Star and should have a tighter blower door test rating in the end... if your focus is Energy Efficiency.
A preliminary blower door test revealed major air leaks in the existing masonry.
Conduct blower door air leakage testing and, where appropriate, duct leakage testing.
But, unless you want to pay for a 2nd blower door test, you won't really know how successful you were.
The furnace blower blower door mounted in a window.
Building my own blower door allows me to take my time finding and sealing leaks and to get a good idea what the leakage rate is for my house.
The major parts of the testing include building envelope leakage (aka blower door test), duct leakage test (Duct Blaster ®), and differential pressurization of zones.
This has been made very clear to me as I've started doing newly required code compliance blower door tests here in Michigan.
With the benefits of greater airtightness in focus as the post-Sandy maelstrom continues, New York City should pass a law that mandates blower door testing and reporting to the Department of Buildings as an essential first step in making airtightness the new normal.
We'll test at as high pressure as two blower door fans will go - 150 + Pa in order to magnify / amplify the leaks.
The first and only blower door test registered a result of 0.56 ACH, comfortably inside the passive house target.
The final blower door test result on the show house of 0.20 — coincidentally in both air changes per hour and m3 / hr / m2 at 50 Pascals — is one of the best results Passive House Plus has ever encountered, in particular for a masonry building.
Similar to a home inspection that can reveal flaws in a property, Gallegos maintains that energy audits, where blower door tests and infrared technologies are used to diagnose the energy efficiency of a home, are an equally important tool for homebuyers because they can reveal areas in a home that waste energy which means higher costs.
This section covers all the aspects of figuring out blower door flow, estimating 50Pa flow, comparing your home tightness to others, and estimating natural infiltration rates, heat loss, and fuel costs:
There's no requirement for blower door or duct leakage testing, which is fine because the state energy code already requires builders to meet minimum thresholds for enclosure - tightness and duct - sealing.
Commercial blower doors are high capacity calibrated fans that are installed in a door in order to measure how leaky your home is and to allow easier spotting of leaks so they can be sealed.
There is a lot out there on blower doors — here are few selected references you might want to look at:
-LSB-...] 7, 2010 First Blower Door Test successfully completed.
The 2012 IECC requires whole - house infiltration testing (i.e. blower door testing).
Using blower door tests and infrared cameras, energy audits measure air leaks and detect air infiltration or missing insulation.
A standard blower door test uses the fan to depressurize the house to 50 Pascal (0.2 inches of water).